DS/EN 50527-1:2016

Procedure til vurdering af eksponering for elektromagnetiske felter for medarbejdere med aktivt implantabelt medicinsk udstyr – Del 1: Generelt


Status:
Gældende
Type:
Standard
Sprog:
Engelsk
Kategori:
Pris fra:
kr. 555,00

Beskrivelse

This European Standard provides a procedure to assess the risk to workers bearing one or more active implantable medical devices from exposure to electric, magnetic and electromagnetic fields at a workplace. It describes how a general risk assessment should be performed and determines whether it is necessary to carry out a detailed risk assessment.
NOTE 1 – This European Standard does not cover indirect effects caused by non active implants.
NOTE 2 – The risk of human exposure to EMF considered is only due to malfunctioning of AIMD. Possibilities of AIMD contribution to the risk, e.g. local modification of the distribution of EMF produced by external source or production of own EMF, are covered by the respective product standards for the AIMD.
Based on specific workplace standards it can be determined whether preventive measures/actions need to be taken to comply with the provisions of Directive 2013/35/EU. The work situation covered is considered to be under normal working conditions including normal operation, maintenance, cleaning and other situations being part of the normal work.
The frequencies covered are from 0 Hz to 300 GHz.
The European Parliament and Council Directive 2013/35/EU will be transposed into national legislation in all the EU member countries. It is recommended that users of this standard consult the national legislation related to this transposition in order to identify the national regulations and requirements. These national regulations and requirements may have additional requirements that are not covered by this standard and take precedence.
NOTE 3 – Performance requirements with respect to active implantable medical devices are excluded from the Scope of this standard. These are defined in the relevant particular standards for active implantable medical devices.
The risk assessment described in this standard is only required if an AIMD-Employee is present.
Active Implantable Medical Devices (AIMDs) are regulated by Directive 90/385/ ...


Antal sider: 36

Udgivet: 2017-01-25

Godkendelsesdato: 2016-12-05

Internationale relationer : EN 50527-1:2016 IDT

ICS: 13.280 - Beskyttelse mod elektromagnetiske felter og stråling 11.040.40 - Implantater til kirurgi, protetik og ortoptik 13.100 - Sikkerhed på arbejdspladsen. Industrihygiejne