DS/EN ISO 3745:2012

Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for anechoic rooms and hemi-anechoic rooms


Status:
Current
Type:
Standard
Language:
English
Price from:
€ 104.72
Legislation:

Legislation

Harmonized under:
  • Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast

Harmonized standards:
Links

Scope

1.1 General
This International Standard specifies methods for measuring the sound pressure levels on a measurement surface enveloping a noise source (machinery or equipment) in an anechoic room or a hemianechoic room.
The sound power level (or, in the case of impulsive or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width onethird
octave or with frequency weighting A applied, is calculated using those measurements, including corrections to allow for any differences between the meteorological conditions at the time and place of the test and those corresponding to a reference characteristic acoustic impedance.
In general, the frequency range of interest includes the onethirdoctave
bands with midband frequencies from 100 Hz to 10 000 Hz. In practice, the range is extended or restricted to frequencies beyond or within these limits, to those between which the test room is qualified for the purposes of the measurements.
1.2 Types of noise and noise sources
The methods specified in this International Standard are suitable for all types of noise (steady, nonsteady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.
The noise source under test can be a device, machine, component or subassembly.
The maximum size of the noise source depends on specified requirements regarding the radius of the hypothetical sphere or hemisphere used as the enveloping measurement surface.
1.3 Test room
The test rooms that are applicable for measurements made in accordance with this International Standard are an anechoic room or hemianechoic
room, also called, respectively, a freefield
test room or hemifreefield test room.


Number of pages: 80

Published: 2012-06-22

Date of approval: 2012-04-27

International relationships : EN ISO 3745:2012 IDT ISO 3745:2012 IDT

ICS: 17.140.01 - Acoustic measurements and noise abatement in general

Item number: M248055


Committees

Committee

  • CEN/TC 211
  • ISO/TC 43/SC 1/WG 28

Danish committee

DS/S-115

Included in

  • Standardpakke - Akustik 4
    Standards Package – Acoustics 4 – Determination of sound power levels and sound energy levels of noise sources using sound pressure